Dragon shift tutorial notes - look around Smaug for documentation (posted on the wall) on crashing systems & Don’t Panic | Dragon shift tutorial notes - look around Smaug for documentation (posted on the wall) on crashing systems & Don’t Panic | ||
'''Every hour you should check the gas target pressure/temperature and the beam intensity on FC4 And the more detail you put into the midas elog the better!!''' | '''Every hour you should check the gas target pressure/temperature and the beam intensity on FC4 And the more detail you put into the midas elog the better!!''' | ||
Note: if the dragon experts are busy tuning or doing other things if someone could make sure that all gets documented that would be amazing!! | |||
'''Beam Intensity and Gas Pressure:''' | '''Beam Intensity and Gas Pressure:''' | ||
- | - If the current drops below the minimum beam intensity for the experiment during a rossum cup reading of FC4 call ops and kindly request that they work on it. Also call them if you see Large fluctuations which indicate unstable beam. Then notify dragon expert. | ||
- For gas target issues/ if it needs to be topped up, contact a DRAGON expert. | - For gas target issues/ if it needs to be topped up, contact a DRAGON expert. | ||
| Line 25: | Line 25: | ||
- New terminal logs into Daenerys. You will need to ssh into Smaug: ''ssh -Y smaug'' | - New terminal logs into Daenerys. You will need to ssh into Smaug: ''ssh -Y smaug'' | ||
- If the DAQ crashes, in any directory on Smaug run `''start_daq.sh''`. | - If the DAQ crashes, in any directory on Smaug run `''start_daq.sh''` to restart the DAQ. You will then need to also restart Rossum. | ||
- If RootBeer is empty/gone, then the DAQ has crashed. | - If RootBeer is empty/gone, then the DAQ has crashed. | ||
| Line 36: | Line 36: | ||
- On Smaug, run `rbdragon`. | - On Smaug, run `rbdragon`. | ||
- Load histograms -> select setup and consult a DRAGON expert for correct plots. | - Load histograms -> select setup and consult a DRAGON expert or the TRIUMF ELOG for correct plots. | ||
- Double-click plots to open. To open multiple, click "Create New" first. | - Double-click plots to open. To open multiple, click "Create New" first. | ||
| Line 60: | Line 60: | ||
'''Starting a New Run:''' | '''Starting a New Run:''' | ||
ONLY START A NEW RUN WITH ROSSUM!!!! (START TASKS START SCHEUDLE) | |||
- Transition page: ensure all status bars are green and connected. | - Transition page: ensure all status bars are green and connected. | ||
| Line 78: | Line 80: | ||
- Restart Rossum if the DAQ crashes: | - Restart Rossum if the DAQ crashes: | ||
- `./ | - `./startRossum.sh` to restart Rossum | ||
- Start tasks, then start schedule. | - Start tasks, then start schedule. | ||
- If auto-start fails, start a run first, then repeat the steps. If that fails call a dragon expert. | - If auto-start fails, start a run first, then repeat the steps. If that fails call a dragon expert. | ||
-If you need to stop the autopilot hit start tasks then stop schedule that way there are cup readings at the end | |||
-START AND STOP '''TASKS''' IS ONLY FOR THE '''FARADAY CUPS''' | |||
-START AND STOP '''SCHEDULE''' IS ONLY FOR '''STARTING AND STOPPING MIDAS RUNS''' | |||
-once you hit start tasks do not touch anything else while rossum is taking the cup readings... it will crash otherwise | |||
Latest revision as of 16:32, 10 December 2025
Dragon Shift Tutorial Notes - Don’t Panic
Note: this is a draft that will continuously be updated in the next day or so… Good luck :)
Dragon shift tutorial notes - look around Smaug for documentation (posted on the wall) on crashing systems & Don’t Panic
Every hour you should check the gas target pressure/temperature and the beam intensity on FC4 And the more detail you put into the midas elog the better!!
Note: if the dragon experts are busy tuning or doing other things if someone could make sure that all gets documented that would be amazing!!
Beam Intensity and Gas Pressure:
- If the current drops below the minimum beam intensity for the experiment during a rossum cup reading of FC4 call ops and kindly request that they work on it. Also call them if you see Large fluctuations which indicate unstable beam. Then notify dragon expert.
- For gas target issues/ if it needs to be topped up, contact a DRAGON expert.
- Target temperature: ~35.9 °C. If spiking, check LN2 cooling; reset in EPICS vacuum system if needed.
Terminal Usage:
- New terminal logs into Daenerys. You will need to ssh into Smaug: ssh -Y smaug
- If the DAQ crashes, in any directory on Smaug run `start_daq.sh` to restart the DAQ. You will then need to also restart Rossum.
- If RootBeer is empty/gone, then the DAQ has crashed.
RootBeer:
If this crashes…
- On Smaug, run `rbdragon`.
- Load histograms -> select setup and consult a DRAGON expert or the TRIUMF ELOG for correct plots.
- Double-click plots to open. To open multiple, click "Create New" first.
- Click "Start Refresh" and "Attach Online" – updates every few seconds with online data.
MIDAS
- Open Chrome in a new window, if not already open – all the bookmarks at the top are important/useful
- MIDAS status lets you know how the run is going.
- If you need to change anything, document this in the MIDAS elog (found on the sidebar of the webpage):
· If there is a drop in beam intensity, gas pressure change, etc., make a log.
· Ideal time for beam operators to take a snapshot of their setup is in between runs or mid-run. Then make an elog that ops took a snapshot.
· If alarms go off, go to the alarms sidebar in MIDAS. If any are red, call a DRAGON expert.
Starting a New Run:
ONLY START A NEW RUN WITH ROSSUM!!!! (START TASKS START SCHEUDLE)
- Transition page: ensure all status bars are green and connected.
- If one is red, the connection failed. Go to programs on side bar and hit start.
- Status page: provides run info.
Rossum:
- Script for autostarting runs every hour.
- Used for checking transmission – should be done at the start of every run.
- Check values for Faraday cups upstream/downstream of the target.
- Restart Rossum if the DAQ crashes:
- `./startRossum.sh` to restart Rossum
- Start tasks, then start schedule.
- If auto-start fails, start a run first, then repeat the steps. If that fails call a dragon expert.
-If you need to stop the autopilot hit start tasks then stop schedule that way there are cup readings at the end
-START AND STOP TASKS IS ONLY FOR THE FARADAY CUPS
-START AND STOP SCHEDULE IS ONLY FOR STARTING AND STOPPING MIDAS RUNS
-once you hit start tasks do not touch anything else while rossum is taking the cup readings... it will crash otherwise
If Things Go Wrong:
- PUT THE FARADAY CUPS IN (labeled FC*** in optics section of EPICS).
- Call ops to insert FC4, or use `fc4in.sh` on Smaug to insert (and `fc4out.sh` to remove).
- Green = in, Grey = out.
Additional Notes:
- Main ISAC control has links to optics, vacuum system pages.
- If you need to start a run first then start Rossum, ENSURE YOU SELECT "WRITE DATA" when restarting the run.
- To add something to striptools, middle-click the parameter, drag it to striptool commands.