New pages
Jump to navigation
Jump to search
- 07:22, 17 July 2025 What to monitor on a DRAGON shift (hist | edit) [3,510 bytes] Mallory Loria (talk | contribs) (Created page with " = Dragon Shift Tutorial Notes - Don’t Panic = Note: this is a draft that will continuously be updated in the next day or so… Good luck Dragon shift tutorial notes - look around Smaug for documentation (posted on the wall) on crashing systems & Don’t Panic '''Every hour you should check the gas target pressure/temperature and the beam intensity on FC4''' '''Beam Intensity and Gas Pressure:''' - Minimum expected beam (for S2013): 0.64 nA. If the current d...") Tag: Visual edit
- 17:14, 10 July 2025 Tune the DRAGON separator (hist | edit) [15,941 bytes] Lennarz (talk | contribs) (Transferred content from old webpage) Tag: Visual edit
- 10:55, 9 July 2025 Signing up for the DRAGON MIDAS Alarm notifications (hist | edit) [228 bytes] Mallory Loria (talk | contribs) (Created page with "To sign up for the MIDAS Alarms go to this directory on '''smaug''': /Users/dragon/online Then in the file: "notify.txt" file add your email and phone number Save the file and then mentally prepare for thousands of emails :)") Tag: Visual edit
- 15:50, 2 July 2025 Checking Transmission, Alignment, and Beam Energy (hist | edit) [3,114 bytes] Mallory Loria (talk | contribs) (Created page with "When the operators are done tuning the beam to DRAGON the first step is always checking the transmission, beam energy and alignment.")
- 10:39, 26 June 2025 Hybrid Detector (hist | edit) [861 bytes] Lennarz (talk | contribs) (Created page with "Ionization chambers and DSSSDs have their own strengths and weaknesses. An ionization chamber has relatively poor resolution compared to the DSSSD but compensates for this with the ability to discriminate recoils from isobaric contaminants by their energy loss signal. A DSSSD has superior energy resolution, timing capabilities, and produces a strong E signal but is often unable to separate isobars which are very close together in kinetic energy. The Hybrid detector will...")
- 13:54, 25 June 2025 ChangeTargetGas (hist | edit) [1,213 bytes] Ben Reed (talk | contribs) (Created page with "Under normal circumstances, Rick Maharaj (rickster@triumf.ca) should be contacted to change the target gas supply and flush the lines. However, we can also do this ourselves in cases where we need to change the target gas outside of normal working hours for example. Below are the instructions for changing the target gas supply from hydrogen to helium and flushing the gas line. 1) Close gas supply line valve 10, located on east side of the gas target. 2) In the gas sha...")
- 13:50, 25 June 2025 Gas Target (hist | edit) [36,725 bytes] Lennarz (talk | contribs) (Revision history. Started transfer of gas target info to wiki page.) Tag: Visual edit
- 12:22, 25 June 2025 End Detectors (hist | edit) [54 bytes] Lennarz (talk | contribs) (Created page with "DSSSD Ionization Chamber Hybrid Detector")